splash-lt it

 

Designed using cutting edge-technologies, the LT-Series ORC power generation modules by Zuccato Energia are a compact and efficient solution for small-scale primary power generation. Available in a models ranging from 100 a 175 kWE, and able to work even under partial load (i.e. thermal input lower than nominal) LT systems use overheated water as a vector fluid and find their ideal field of application in association with biomass-fueled boilers, as well as for waste heat recovery from furnaces, ovens and industrial processes .

Technical Specifications

Technical Specifications

General Specifications ZE-75-LT ZE-100-LT ZE-150-LT ZE-175-LT
Thermal Power Input 550 kWT 770 kWT 1100 kWT 1280 kWT
Electric Power Output 75 kWE 100 kWE 150 kWE 175 kWE
System Efficiency 13.6 % 13.0 % 13.6 % 13.6 %
Vector Fluid
Overheated Water
Vector fluid input temperature
≥160 °C
Vector fluid output Temperature 145 °C 140 °C
Nominal Vector Fluid Flow Rate 8,49 kg/s 9,84 kg/s 13,14 kg/s 14,88 kg/s
Working Fluid
Environment-friendly, non-flammable HFC mix
Skid Dimensions (L x W x H) 4.95m x 2.15m x 2.80m
Weight (including working fluid) ~ 5000 Kg
Condenser Specifications
Type Brazed plate, in AISI 316 s/s and 99,9% copper
Dissipated Thermal Power 471 kWT 653 kWT 940 kWT 1075 kWT
Input Water Temperature 32 °C 26 °C
Output Water Temperature 40 °C 36 °C
Circuit Flow Rate 14,07 kg/s 15,60 kg/s 22.46 Kg/s 25.69 Kg/s
Generator Specifications
Type Synchronous, permanent magnets, water cooled
Power Output 75 kWE 100 kWE 150 kWE 175 kWE
Rotational speed 15 000 rpm (12...18 Krpm)
Output Voltage 525 VAC
Required Water Cooling 15 kWT
Cooling Water Temperature < 40°C
Cooling Water Flow Rate 30l/min
Additional Cooling (opt.) Working fluid injection
Gas tight up to PN 6 bar
Inverter Specifications
Type IGBT, mains-synchronized, air-cooled, complete with braking chopper.
Power Output 75 kWE 100 kWE 150 kWE 175 kWE
Output Voltage
400 V AC +5% tol.
Output Frequency 50 Hz +0.5% tol.
Environment temperature <40 °C
Braking chopper Built-in, on resistors
Turbine Specifications
Type Radial, fixed nozzles, directly coupled to generator.
Working fluid input temperature 145 °C
Working fluid output temperature ∼ 100 °C
Stage pressure PS 16 bar (tested up to 24 bar)
Turbine body material
Welded steel
Impeller material Aluminium alloy
Speed control DC bus voltage
Impeller seal Labyrinth seal on impeller backside
Generator seal Axial labyrinth seal on generator interface (opt.)
Environmental seals Static and O-ring seals
Working Fluid Specifications
Working temperature
60°C < T <165 °C
Condensation temperature ≤ 33 °C
Operating pressure ≤ 20 bar
Toxicity Non-toxic
Biodegradability 100%
Impact on ozone layer None ("ozone friendly")

Documentation

Documentation

Commercial brochures and technical datasheets are available for the LT range of products.  You can download them from the links below or from our Documentation page.

 

Brochure Serie ULH

LT Range Products Brochure
English Language
PDF Format, ≈3.1 Mb

 

 

Scheda Tecnica ZE100

ZE-100-LT Tech Datasheet
English Language
PDF Format, ≈1.2 Mb

 

 

Scheda Tecnica ZE150

ZE-150-LT Tech Datasheet
English Language
PDF Format, ≈1.2 Mb

 

 

Scheda Tecnica ZE175

ZE-175-LT Tech Datasheet
English Language
  PDF Format, ≈1.2 Mb


Video

Video

The following is a product video of the ZE-150-LT Energy Production Module. Further videos are available from Zuccato Energia's YouTube channel.

We did our best to make sure that these data are correct and up-to-date; however, they must be considered as purely indicative, non-binding and subject to change without notice.